{"product_id":"ge-multilin-c60tg3hlh-breaker-protection-relay","title":"GE Multilin C60TG3HLH Breaker Protection Relay","description":"\u003cp\u003eConfigured for high-voltage breaker management in Universal Relay (UR) platforms, the \u003cstrong\u003eGE Multilin C60TG3HLH\u003c\/strong\u003e (\u003cstrong\u003eC60TG3HLH\u003c\/strong\u003e Breaker Protection Relay) provides direct physical and electrical execution of circuit breaker monitoring, protection, and control schemes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eC60TG3HLH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard UR relay chassis form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRelay backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBreaker failure, trip supervision, sync check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The relay utilizes the high-speed UR backplane bus for internal module-to-module data synchronization. This velocity is necessary to maintain deterministic protection logic execution, ensuring that breaker trip signals are processed within sub-cycle time windows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e The C60TG3HLH supports high-speed integration into modern automation networks via protocols such as IEC 61850 Edition 2 and Modbus TCP. This enables deterministic data exchange with SCADA or DCS platforms for remote monitoring and supervisory control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The device architecture permits the expansion of digital I\/O through additional UR platform modules, allowing for the scaling of breaker monitoring points in complex substation configurations like breaker-and-a-half or ring bus schemes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The processor board supports field-upgradeable firmware, facilitating ongoing compliance with evolving cybersecurity standards and protocol revisions without requiring hardware replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does FlexLogic™ enhance substation automation?\u003c\/p\u003e\n\u003cp\u003eA: FlexLogic™ provides a programmable, graphical, or Boolean-based environment that allows engineers to create custom automation logic. It is used to implement complex interlocking sequences, automatic reclosing patterns, and specialized breaker failure schemes that are not native to fixed-function relays.\u003c\/p\u003e\n\u003cp\u003eQ: Does the C60TG3HLH require external hardware for synchronism check functions?\u003c\/p\u003e\n\u003cp\u003eA: No, the C60TG3HLH features integrated synchronism check logic. It monitors voltage and phase angle across the breaker contacts to ensure conditions are met before permitting a close command, preventing out-of-phase synchronization events.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the relay chassis into the substation rack or cabinet using the designated mounting hardware. Ensure the chassis is properly leveled to facilitate cooling airflow through the internal ventilation apertures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the relay chassis to the substation earth grid using a low-impedance ground cable. A solid ground connection is mandatory to ensure the efficacy of internal surge suppression and to protect the internal digital logic from electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain strict physical separation between high-voltage CT\/VT signals and low-voltage control\/communication wiring. Use shielded, twisted-pair cabling for all communication loops to mitigate inductive noise ingress that could otherwise compromise the integrity of networked data.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47981309132990,"sku":"C60TG3HLH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-05_17-48-06_5b3cb137-a2d5-431c-8a41-01455d1388af.png?v=1783419113","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-multilin-c60tg3hlh-breaker-protection-relay","provider":"AutoOilTech Limited","version":"1.0","type":"link"}