{"product_id":"ge-is200stcih6a-simplex-contact-input-terminal-board","title":"GE IS200STCIH6A Simplex Contact Input Terminal Board","description":"\u003ch2\u003eGE IS200STCIH6A Contact Input Terminal Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for simplex contact input acquisition in Mark VIe distributed control systems, the \u003cstrong\u003eGE IS200STCIH6A\u003c\/strong\u003e (\u003cstrong\u003eIS200STCIH6A\u003c\/strong\u003e Contact Input Terminal Board) provides direct electrical interfacing for 24 dry‑contact channels stimulated at nominal \u003cstrong\u003e24 VDC\u003c\/strong\u003e, \u003cstrong\u003e48 VDC\u003c\/strong\u003e, or \u003cstrong\u003e125 VDC\u003c\/strong\u003e, with integrated suppression for surge and high‑frequency noise.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe provided documentation does not define any suffix variants or model matrix for \u003cstrong\u003eIS200STCIH6A\u003c\/strong\u003e. The board is treated as a single, fixed hardware configuration within the Mark VIe platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200STCIH6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e15.9 cm high x 10.2 cm wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified (powered through PAIC I\/O pack interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eContact Input Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e24 dry‑contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInput Voltage Levels\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNominal 24 VDC, 48 VDC, 125 VDC stimulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTechnology\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSurface‑mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNoise Suppression\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eSurge and high‑frequency filtering on each input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eI\/O Pack Compatibility\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePAIC I\/O pack via D‑type connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VIe and Mark VIeS simplex systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eInstallation Method\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDIN‑rail or sheet‑metal carrier with plastic insulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eDirect terminal block wiring; typical #18 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eShield Termination\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eShields routed to a dedicated bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity Licences\u003c\/h3\u003e\n\u003cp\u003eAs a GE industrial control module, the IS200STCIH6A participates in deterministic Mark VIe I\/O acquisition cycles. The PAIC I\/O pack communicates through a D‑type connector and forwards contact state changes over \u003cstrong\u003eEtherNet\/IP deterministic networks\u003c\/strong\u003e to the controller. The board’s 24‑channel density aligns with \u003cstrong\u003eI\/O density scaling\u003c\/strong\u003e across Mark VIe cabinets, while its surface‑mount design maintains compatibility with \u003cstrong\u003efirmware flash compatibility\u003c\/strong\u003e requirements for PAIC modules. Noise suppression at each input ensures stable propagation timing even under high‑frequency interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IS200STCIH6A be hot‑swapped during operation?\u003c\/strong\u003e A: No. The board is mechanically mounted and directly wired; all circuits must be de‑energized before removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the PAIC I\/O pack require configuration changes when replacing the board?\u003c\/strong\u003e A: No. The PAIC automatically detects the terminal board through the D‑type interface. Only wiring verification is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the board handle high‑frequency noise on contact inputs?\u003c\/strong\u003e A: Each channel includes suppression circuitry that filters surge and high‑frequency disturbances before the signal reaches the PAIC pack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board on a DIN‑rail carrier or sheet‑metal assembly using the provided insulator.\u003c\/li\u003e\n\u003cli\u003eUse #18 AWG wiring for contact inputs unless cabinet standards specify otherwise.\u003c\/li\u003e\n\u003cli\u003eTerminate shields on the designated bracket to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between contact wiring and high‑energy conductors to reduce induced noise.\u003c\/li\u003e\n\u003cli\u003eVerify correct seating of the D‑type connector to ensure stable Ethernet communication through the PAIC pack.\u003c\/li\u003e\n\u003cli\u003eInspect terminal screws for proper torque after installation to avoid intermittent contact states.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48142100955326,"sku":"IS200STCIH6A","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/general-electric-is200srtdh2acb-drl-termbd-rtd-j2rkfm22rdq.png?v=1759132300","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200stcih6a-simplex-contact-input-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}