{"product_id":"ge-is200jpdeg1aaa-dc-battery-power-distribution-board","title":"GE IS200JPDEG1AAA DC Battery Power Distribution Board","description":"\u003ch2\u003eGeneral Electric IS200JPDEG1AAA Mark VIe Series DC Battery Power Distribution Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGeneral Electric IS200JPDEG1AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200JPDE\u003c\/strong\u003e DC Battery Power Distribution Board, operates as a dedicated hardware component for DC power distribution and fault monitoring within Mark VIe PDM (Power Distribution Modules) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200JPDEG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard industrial weight for Mark VIe JPDE boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.08 cm wide x 16.51 cm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower distributed from external battery\/supply, supports 24 VDC or 48 VDC modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e18 - 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003e1,500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage Rejection\u003c\/td\u003e\n\u003ctd\u003e60 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and System Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IS200JPDEG1AAA routes DC power paths across a maximum of 24 channels while sustaining backplane bus communication velocity and diagnostics via P1\/P2 feedback connectors. These linkages tie into the JPDB, JPDF, JPDS, and JPDM modules, transmitting core electrical metrics directly to the PPDA I\/O pack. The architecture incorporates dual 50-pin diagnostic connectors positioned on both the upper and lower boundaries of the board, allowing structural data acquisition and real-time power bus monitoring. This dual-connector loop facilitates deterministic tracking of the floating DC bus configuration, which is mechanically centered on earth ground using a discrete resistor network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IS200JPDEG1AAA manage system ground fault detection?\u003c\/p\u003e\n\u003cp\u003eA: The board establishes a floating DC bus centered on earth ground via a network of onboard resistors. Voltage feedback is routed continuously through the PPDA I\/O pack to calculate ground fault deviations.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary isolation and rejection boundaries for this module?\u003c\/p\u003e\n\u003cp\u003eA: The board provides galvanic input isolation rated at 1,500 V and features an AC voltage rejection threshold of 60 V RMS to prevent noise propagation across the DC distribution lines.\u003c\/p\u003e\n\u003cp\u003eQ: Does this board provide input power for bulk 500W power supplies?\u003c\/p\u003e\n\u003cp\u003eA: No, the current passing capabilities of this board's conventional construction limit its output paths; it does not supply power to bulk 500W (24 V input\/28 V output) supplies that drive I\/O pack control power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation and Base Grounding:\u003c\/strong\u003e Secure the board vertically onto the metal bracket within the PDM cabinet using the integrated DIN-rail mounting interfaces. Ensure that the sheet metal bracket establishes direct, unpainted metal-to-metal contact with the underlying base to verify solid functional earth (FE) grounding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Cable Interfacing:\u003c\/strong\u003e When connecting to the top and bottom 50-pin diagnostic connectors, verify cable strain reliefs are clamped. Avoid routing diagnostic ribbons parallel to high-current DC output wires to reduce inductive coupling risks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Configuration Checks:\u003c\/strong\u003e Verify that all upstream supply limits match the targeted 18 - 32 VDC operating range before energizing the board. Ensure feedback lines to the JPDB, JPDF, JPDS, or JPDM connectors are keyed properly to maintain loop telemetry alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Constraints:\u003c\/strong\u003e Maintain clean convective airflow profiles within the cabinet. Do not block the top or bottom edges of the surface-mount module assembly, keeping ambient localized temperatures between 0 to 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47901235118270,"sku":"IS200JPDEG1AAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-30_10-41-59_a868b064-a655-44a9-a5c8-2e7cc5c56d62.png?v=1782787591","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200jpdeg1aaa-dc-battery-power-distribution-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}