{"product_id":"ge-is200jpdcg1a-power-distribution-board","title":"GE IS200JPDCG1A Power Distribution Board","description":"\u003ch1\u003eGE IS200JPDCG1A Power Distribution Board\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eGE IS200JPDCG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eJPDC\u003c\/strong\u003e Power Distribution Module, is a critical component in the Mark VI \/ Mark VIe Speedtronic Control Systems, designed to manage and distribute multiple voltage domains across turbine control architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eIS200JPDCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMark VI \/ Mark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Acronym\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eJPDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePower Distribution Module \/ Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e28 VDC (distribution), plus 125 VDC and 115\/230 VAC routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMetal sub-panel via standoffs and screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eScrew terminals, stab-on connectors, multi-pin plug assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eToggle Switches\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e7 independent switches (sequential\/delay lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eTerminal Strips\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eOne 5-position strip, three 3-position auxiliary strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eFuses, surge suppression, isolation networks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSafety Delay\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e30-second re-energization wait requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eManual Reference\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eGEH-6721G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe IS200JPDCG1A consolidates input and output functions from prior designs to distribute \u003cstrong\u003e125 VDC, 115\/230 VAC, and 28 VDC\u003c\/strong\u003e rails to downstream boards and I\/O packs. It ensures isolation between power domains and integrates protective elements such as fuses, surge suppression, and isolation networks to safeguard against electrical faults and overloads.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHosts \u003cstrong\u003ePPDA Power Distribution System Feedback pack\u003c\/strong\u003e within Mark VIe systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReceives diagnostic feedback signals from other distribution boards and routes them to the PPDA I\/O pack.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for direct PPDA mounting; no provision for transmitting diagnostics to other distribution boards.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMount vertically with the \u003cstrong\u003e115\/230 VAC input connector (JAC)\u003c\/strong\u003e at the bottom.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure with four screws via mounting holes at the top and bottom of the base.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTypically installed low in the cabinet to facilitate grounding.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional PPDA I\/O pack connects to \u003cstrong\u003eJA1\u003c\/strong\u003e and is secured with an angle bracket and threaded studs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostic feedback routed via \u003cstrong\u003e50-pin ribbon cable (P2)\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat is GE IS200JPDCG1A?\u003c\/strong\u003e  A 28 VDC Power Distribution Board for Mark VI\/Mark VIe platforms, managing branch power routing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhy the 30-second warning label?\u003c\/strong\u003e  Ensures capacitors discharge fully before re-energization, preventing hardware stress.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow does it mount inside a control panel?\u003c\/strong\u003e  Using standoffs and screw tracks on a rigid metal sub-panel.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat connector styles are available?\u003c\/strong\u003e  Screw terminals, stab-on male terminals, and multi-pin plug ports.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat voltage does it distribute?\u003c\/strong\u003e  Primarily 28 VDC, with additional routing for 125 VDC and 115\/230 VAC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48420936122558,"sku":"IS200JPDCG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-30_10-41-59.png?v=1782787591","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200jpdcg1a-power-distribution-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}