{"product_id":"ge-is200epdmg1baa-mark-vi-terminal-board","title":"GE IS200EPDMG1BAA Mark VI Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200EPDMG1BAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200EPDMG1BAA\u003c\/strong\u003e Terminal Board, operates as a dedicated hardware component for turbine control signal distribution within Speedtronic Mark VI gas and steam turbine management platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: IS200EPDMG1BAA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model\u003c\/strong\u003e: IS200EPDM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Version\u003c\/strong\u003e: G1BAA standard rectangular board configuration supporting terminal connections and throughput protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EPDMG1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eTurbine Control and Terminal Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAuthorized Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard printed circuit board weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard rectangular Mark VI board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial cabinet environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003eDual terminal blocks, multiple inline fuses, eight diagnostic LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Backplane Network Execution\u003c\/h3\u003e\n\u003cp\u003eEngineered to interface directly with Speedtronic Mark VI controller racks, the IS200EPDMG1BAA operates with backplane bus communication velocity licences to support deterministic data exchanges across Simplex and Triple Modular Redundant (TMR) architectures. The board manages local signal distribution while maintaining firmware flash compatibility across distributed turbine nodes. I\/O density scaling is preserved through dedicated female plug connectors and integrated metal oxide varistors for transient voltage suppression.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200EPDMG1BAA board support live hot-insertion replacement within an active Mark VI rack?\u003c\/p\u003e\n\u003cp\u003eA: Power must be completely isolated prior to board extraction or insertion to prevent electrical transients and protect sensitive circuit components.\u003c\/p\u003e\n\u003cp\u003eQ: How is operational status visually verified on the board?\u003c\/p\u003e\n\u003cp\u003eA: Eight green LED indicators lined up along the edge of the board illuminate to verify that internal circuitry is energized.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely inside a grounded industrial control cabinet designed for Mark VI turbine management infrastructure. Ensure that all terminal block wiring and female plug connectors are inspected for secure physical contact prior to system energization. Verify that protective fusing and metal oxide varistors are intact to maintain throughput safeguarding against electrical faults.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48359567458494,"sku":"IS200EPDMG1BAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-08-03_17-41-50.png?v=1785750554","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200epdmg1baa-mark-vi-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}