{"product_id":"ge-is200ehpag1aed-mark-vi-exciter-board","title":"GE IS200EHPAG1AED Mark VI Exciter Board","description":"\u003cp\u003eConfigured for excitation control in power automation systems, the \u003cstrong\u003eGE IS200EHPAG1AED\u003c\/strong\u003e (\u003cstrong\u003eIS200EHPAG1AED\u003c\/strong\u003e Exciter Board) provides direct physical\/electrical execution across GE Mark VI control platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: IS200EHPAG1AED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model\u003c\/strong\u003e: IS200EHPA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Version\u003c\/strong\u003e: G1AED standard configuration featuring Mark VI exciter board circuitry for power generation systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EHPAG1AED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eIndustrial Control and Excitation Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExciter Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAuthorized Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard industrial printed circuit board weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark VI board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane excitation power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Performance\u003c\/td\u003e\n\u003ctd\u003ePrecise excitation control, DIN rail mountable, -40 deg C to +70 deg C storage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Backplane Network Execution\u003c\/h3\u003e\n\u003cp\u003eEngineered to integrate directly into GE Mark VI control architectures, the IS200EHPAG1AED operates with backplane bus communication velocity licences to support deterministic data exchanges. The board executes high-speed signal processing for rotor excitation loops while maintaining firmware flash compatibility across distributed turbine control nodes. I\/O density scaling is managed natively to preserve high-precision signal feedback across high-voltage generation assets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IS200EHPAG1AED board support hot-insertion replacement within an active Mark VI rack?\u003c\/p\u003e\n\u003cp\u003eA: Power must be isolated prior to board extraction or insertion to prevent backplane transient damage and ensure hardware protection.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental monitoring is required for this exciter board installation?\u003c\/p\u003e\n\u003cp\u003eA: Ambient operating temperatures must remain strictly between -10 deg C and +55 deg C with relative humidity levels maintained below 95% non-condensing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely using standard DIN rail installation procedures inside a grounded industrial control cabinet. Ensure that all backplane connectors are fully seated and free from particulate contamination prior to system energization. Route internal control wiring away from high-current power stages to prevent electromagnetic interference and maintain signal integrity.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48359407059134,"sku":"IS200EHPAG1AED","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200EGDMH1ACB_a611b597-8984-4a52-89a6-ce77fe4b046e.png?v=1785750444","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200ehpag1aed-mark-vi-exciter-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}