{"product_id":"ge-is200ectbg1acb-terminal-board","title":"GE IS200ECTBG1ACB Terminal Board","description":"\u003cp\u003eConfigured for excitation contact input and output control in EX2100 Excitation Control platforms, the \u003cstrong\u003eGeneral Electric IS200ECTBG1ACB\u003c\/strong\u003e (\u003cstrong\u003eIS200ECTBG1ACB\u003c\/strong\u003e Exciter Contact Terminal Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model \u003cstrong\u003eIS200ECTBG1ACB\u003c\/strong\u003e belongs to the General Electric EX2100 Series excitation control architecture. Based on standard part number configuration rules, the base designation identifies the Exciter Contact Terminal Board form factor, while the specific suffix string encodes the revision level, hardware assembly configuration, and deployment compatibility exclusively for redundant control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ECTBG1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.00 x 9.00 x 3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow-Power Logic and Relay Driver Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Coil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Relay Contact Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Relay Contact Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe terminal board coordinates signal distribution across the excitation control framework, executing deterministic data fan-out to the M1, M2, and C controllers. Configurable firmware flash and manual compatibility via reference manual GEI-100457A ensure synchronized network integration. Backplane bus communication velocity and signal isolation maintain low latency during trip relay activation and auxiliary contact monitoring across redundant control architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the terminal board support hot-swap replacement under live system power?\u003c\/p\u003e\n\u003cp\u003eA: No, control power and field wetting voltage supplies must be completely de-energized prior to handling or replacing the \u003cstrong\u003eGeneral Electric IS200ECTBG1ACB\u003c\/strong\u003e board to prevent electrical shock and bus logic faults.\u003c\/p\u003e\n\u003cp\u003eQ: How are the trip relays configured on the ECTBG1 variant?\u003c\/p\u003e\n\u003cp\u003eA: The board controls two trip relays (labeled K1M1 and K2M1) using Form-A configurations with two parallel normally closed contacts, powered by 24 VDC from the M1 controller.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the terminal board securely within the designated EX2100 control cabinet enclosure, ensuring proper physical clearance around the 11.00 x 9.00 x 3.00 dimensions. Route external 70 VDC wetting voltage lines and digital control cabling separately from high-voltage AC power conduits to minimize electromagnetic interference. Verify that terminal block screw torques and grounding connections are fully secured prior to system energization.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48235064230078,"sku":"IS200ECTBG1ACB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IS200ACLEH1ACB_IS215ACLEH1A_82b9cb20-676e-481d-8626-f564e1fa992d.png?v=1785465405","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200ectbg1acb-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}