{"product_id":"ge-is200aepah1bfc-printed-circuit-board","title":"GE IS200AEPAH1BFC Printed Circuit Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE IS200AEPAH1BFC (IS215WEPAH2BA)\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIS200AEPAH1BFC\u003c\/strong\u003e Printed Circuit Board utilized to execute signal processing and communication across GE Mark VIe Wind Turbine Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Element\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation \/ Value\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Model\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1BFC\u003c\/td\u003e\n\u003ctd\u003eMain printed circuit board assembly identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Board ID\u003c\/td\u003e\n\u003ctd\u003eIS215WEPAH2BA\u003c\/td\u003e\n\u003ctd\u003eSecondary layout or hardware variant sub-designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003ePCB\u003c\/td\u003e\n\u003ctd\u003eDedicated printed circuit board hardware component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1BFC (IS215WEPAH2BA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing Plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152 x 44 x 290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range (0 deg C to 60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 125 VDC rack supply rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Rating\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Frame Rates\u003c\/td\u003e\n\u003ctd\u003e10 ms, 20 ms, and 40 ms execution intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Types\u003c\/td\u003e\n\u003ctd\u003eIONet and UDH (Universal Data Highway)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eOperating within Mark VIe control architectures, the circuit board coordinates deterministic network communications over IONet and Universal Data Highway (UDH) links. Firmware flash compatibility and hardware revision alignment ensure synchronized frame rates operating at 10 ms, 20 ms, and 40 ms cycles. Real-time diagnostic LEDs and internal signal conditioning pathways isolate control logic from high-voltage transients while maintaining high-speed data throughput across backplane interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication networks are supported by the IS200AEPAH1BFC board?\u003c\/p\u003e\n\u003cp\u003eA: The board supports high-speed IONet and Universal Data Highway (UDH) network protocols for turbine control communication.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply rating is required to energize this printed circuit board?\u003c\/p\u003e\n\u003cp\u003eA: The hardware operates using a nominal 125 VDC power supply rail delivered through the rack backplane assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What software execution frame rates are supported during runtime operation?\u003c\/p\u003e\n\u003cp\u003eA: The board accommodates deterministic software frame rates configured at 10 ms, 20 ms, and 40 ms intervals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure rack power is completely turned off before inserting or removing the IS200AEPAH1BFC board from the Mark VIe chassis. Handle the printed circuit board strictly by its edges while wearing an ESD-safe wrist strap to prevent electrostatic damage. Align the module carefully with chassis card guides, push firmly to engage backplane connectors, and secure retention screws to maintain mechanical and electrical ground continuity.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48231521353918,"sku":"IS200AEPAH1BFC (IS215WEPAH2BA)","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-17_11-37-55_415ffbdb-9c52-4ba2-9448-8839aaf90c8f.png?v=1785399583","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-is200aepah1bfc-printed-circuit-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}