{"product_id":"ge-ic695pns001-scanner-modules","title":"GE IC695PNS001 Scanner Modules","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC695PNS001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PNS001\u003c\/strong\u003e PROFINET Scanner Module, operates as a dedicated hardware component for remote I\/O data routing and network protocol execution within RX3i PacSystem platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PNS001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.71 kg (1.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSingle-slot RX3i Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.1 A at 5 VDC, 1.2 A at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocols\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e4 Switched Ports (2 RJ-45, 2 SFP Cages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100\/1000 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topologies\u003c\/td\u003e\n\u003ctd\u003eLinear, Star, Daisy Chain, Redundant Ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eProficy Machine Edition 8.50 or later, optional SD card transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Port\u003c\/td\u003e\n\u003ctd\u003e1 Micro USB (firmware upgrades only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Synchronization\u003c\/h3\u003e\n\u003cp\u003eInterfacing through the RX3i universal backplane, the module maintains deterministic backplane bus communication velocity while scanning remote I\/O modules and exchanging process variables with host CPUs. The 4-port switched Ethernet architecture supports PROFINET deterministic networks across linear, star, and ring configurations. High I\/O density scaling is preserved across multi-rack setups without introducing data latency, while firmware flash compatibility via Micro USB or SD card storage maintains network time alignment and parameter consistency across redundant nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the front-panel Micro USB port?\u003c\/p\u003e\n\u003cp\u003eA: The Micro USB port is dedicated exclusively to local firmware flash upgrades using maintenance software tools and is not intended for operational SCADA or programming connections.\u003c\/p\u003e\n\u003cp\u003eQ: How is hardware configuration transferred between PNS modules during field replacement?\u003c\/p\u003e\n\u003cp\u003eA: Device names, IP addresses, and network parameters can be stored on a compatible SD card, allowing direct hardware parameter transfer to a replacement module without re-commissioning via Proficy Machine Edition.\u003c\/p\u003e\n\u003cp\u003eQ: What power rails does the module draw from the RX3i backplane bus?\u003c\/p\u003e\n\u003cp\u003eA: The module draws an internal current load of 1.1 A from the 5 VDC bus and 1.2 A from the 3.3 VDC bus of the universal backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the host RX3i rack power supply before inserting or removing the single-slot module from the backplane.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the designated backplane slot guides and press firmly until the rear connector fully seats into the universal backplane.\u003c\/li\u003e\n\u003cli\u003eTighten the top and bottom retaining screws to 0.8 Nm torque to establish a solid ground path with the metallic rack frame.\u003c\/li\u003e\n\u003cli\u003eRoute optical fiber and Category 6 Ethernet cables through cable management channels, maintaining single-point shield grounding on copper media to mitigate high-frequency electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48786276221118,"sku":"IC695PNS001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/IC695PNS001.png?v=1787710226","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ic695pns001-scanner-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}