{"product_id":"ge-ic695mdl765-smart-digital-output-module","title":"GE IC695MDL765 Smart Digital Output Module","description":"\u003cp\u003eConfigured for high-density discrete signal execution in PACSystems RX3i control platforms, the \u003cstrong\u003eGE IC695MDL765\u003c\/strong\u003e (\u003cstrong\u003eIC695MDL765\u003c\/strong\u003e Smart Digital Output Module) provides direct physical\/electrical execution of 24\/125 Vdc output control and Electronic Short Circuit Protection (ESCP) for 16 discrete points.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695MDL765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.50 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eController backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e16 points, 24\/125 VDC, 1A ESCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The module utilizes the high-speed PCI-based RX3i backplane, enabling deterministic data exchange between the CPU and the output points. This velocity is necessary to support high-speed switching requirements in automated production environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e When integrated into an RX3i remote I\/O rack, the module facilitates deterministic output state updates over industrial Ethernet networks. The module's internal logic handles point-to-point state processing with minimal propagation delay, ensuring synchronous operation across distributed I\/O stations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The 16-point architecture allows for efficient control cabinet layout, supporting high-density logic execution within a single RX3i rack slot while providing granular electronic protection for each channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The module supports field-upgradeable firmware, ensuring ongoing compatibility with evolving controller platform revisions and maintaining the security and functional integrity of the output control logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ESCP (Electronic Short Circuit Protection) require manual resetting?\u003c\/p\u003e\n\u003cp\u003eA: No, the ESCP is an electronic protection feature. Once a short circuit or overcurrent condition is cleared from the field side, the module is designed to reset automatically, though the specific fault must be acknowledged in the controller software to restore normal output operations.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the IC695MDL765 supports hot-insertion and extraction within the RX3i backplane. Ensure that the module is properly seated and the locking mechanism is engaged to maintain bus communication and prevent intermittent output states during the transition.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the module into the designated RX3i rack slot, ensuring the backplane connector pins are fully mated. Use the integrated release latches to lock the module in place, providing mechanical support against vibration and thermal expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Terminate the module's common return and chassis ground pins to the cabinet's low-impedance earth bus. This is mandatory for the effective operation of the ESCP circuits and to provide a robust return path for high-frequency switching currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize shielded cabling for long output runs to mitigate inductive interference. Keep discrete output lines separated from high-voltage AC cabling by at least 150 mm to prevent crosstalk and ensure the integrity of the 125 Vdc signal levels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47981534871742,"sku":"IC695MDL765","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-07_17-37-14.png?v=1783419222","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ic695mdl765-smart-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}