{"product_id":"ge-ic695cpl410-aaac-cpu-processors","title":"GE IC695CPL410-AAAC CPU Processors","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC695CPL410-AAAC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695CPL410\u003c\/strong\u003e Controller CPU, operates as a dedicated hardware component for central processing and logic execution within PACSystems RX3i control networks. The unit executes real-time control algorithms, coordinates high-speed backplane transactions, and manages deterministic communication links across connected distributed I\/O manifolds and drive systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CPL410-AAAC (IC695CPL410)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE \/ Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e7.2 cm x 13.3 cm x 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i Controller CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated high-performance embedded control processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003ePCI-based RX3i universal backplane system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via backplane power supply module rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Dynamics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Processing Execution:\u003c\/strong\u003e The CPU architecture is designed for high-density control configurations, executing fast boolean logic sweeps and floating-point math routines over a PCI-based parallel backplane. The internal memory structure operates synchronously with the backplane bus communication velocity parameters, enabling deterministic I\/O updates and rapid application processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet and EtherNet\/IP Deterministic Networks:\u003c\/strong\u003e The controller features embedded Ethernet interfaces supporting deterministic communication network protocols such as Profinet and EtherNet\/IP. This integrated communication layer provides microsecond-level updates for critical control points, maintaining data synchronization across distributed field buses without adding extra communication modules to the host rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC695CPL410-AAAC handle user application code storage during a system power dropout?\u003c\/p\u003e\n\u003cp\u003eA: The controller utilizes onboard non-volatile flash memory storage coupled with an internal power backup mechanism. Upon a power failure, all user logic configurations, register states, and system firmware are safely written to flash memory, eliminating the need for an external lithium battery backup.\u003c\/p\u003e\n\u003cp\u003eQ: Is the firmware flash compatibility backward-compatible with older RX3i programming software versions?\u003c\/p\u003e\n\u003cp\u003eA: Firmware versions for the IC695CPL410 series require specific baseline revisions of the master programming software. Prior to updating or flashing the CPU firmware, check the compatibility matrix to ensure the development tool version can fully compile and track the updated register structures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Layout Alignment, Clearance Constraints, and Mechanical Seating:\u003c\/strong\u003e Line up the 0.45 kg CPU module with the designated master slot tracks of the RX3i universal backplane. Slide the unit firmly backward until the high-density PCI pins sit square within the backplane connector, and engage the top and bottom mechanical retention levers. Maintain a minimum 50 mm clearance perimeter above and below the module face to facilitate passive convective heat dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation, Wireway Constraints, and Shield Grounding:\u003c\/strong\u003e Route all communication and programming network cables inside dedicated, low-voltage wire ducts separated from high-current AC mains feeds or variable speed drive output wires. Connect the main backplane chassis grounding stud directly to the control cabinet's primary copper earth bus using a heavy, low-resistance grounding strap to shield the internal processor from stray high-frequency electromagnetic noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47901795451070,"sku":"IC695CPL410-AAAC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-01_17-42-33_30b403a6-59bb-4a65-aee5-64f362bc8774.png?v=1782899887","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ic695cpl410-aaac-cpu-processors","provider":"AutoOilTech Limited","version":"1.0","type":"link"}