{"product_id":"ge-ds200tbcag1aaa-rtd-termination-module","title":"GE DS200TBCAG1AAA RTD Termination Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200TBCAG1AAA\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TBCAG1AAA\u003c\/strong\u003e RTD Termination Module, operates as a dedicated hardware component for field-to-controller signal routing within Mark V DS200 Speedtronic control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eMark V Series identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTBCA\u003c\/td\u003e\n\u003ctd\u003eTermination Board, Core Analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eRevision level 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAAA\u003c\/td\u003e\n\u003ctd\u003eFunctional configuration iteration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBCAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 x 100 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive signal termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003e52 termination points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Industrial Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The module serves as a passive termination interface for the TCCB board. Signal transit latency is minimized to maintain high-speed sampling rates necessary for deterministic turbine protection logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e While the module is hardware-analog, it provides the clean signal path required for downstream conversion to digital fieldbus protocols within the Mark V rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The 52-point termination density is optimized for high-density analog input monitoring, allowing for modular scaling of temperature-sensing circuits within position seven of the core cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e As a passive termination component, the module requires no firmware; it maintains electrical transparency, ensuring full compatibility across all Mark V TCCB board revisions and software versions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TBCAG1AAA require power for operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The module is a passive termination board designed for routing analog RTD signals. Power is provided only to the localized signal loops by the connected TCCB board.\u003c\/p\u003e\n\u003cp\u003eQ: Can the jumper settings for 0-1 mA input be changed while the system is under load?\u003c\/p\u003e\n\u003cp\u003eA: No. Any modification to configuration jumpers must be performed with the control rack de-energized. Adjusting jumpers while the circuit is active can result in signal transients or potential damage to the TCCB input stages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Utilize the integrated bayonet connectors to seat the module securely within the cabinet rack. Proper mechanical seating is mandatory to ensure low-contact-resistance paths for sensitive RTD temperature signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure the module chassis is bonded to the cabinet’s analog ground reference. This is mandatory to prevent ground-loop-induced noise from injecting errors into the 4-20 mA or 0-1 mA measurement circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate field-side RTD leads to the 52 terminal points using appropriate strain relief. Maintain a minimum separation of 150 mm from high-voltage AC cabling to prevent inductive coupling, which is critical for protecting the accuracy of the temperature measurement signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48079064170686,"sku":"DS200TBCAG1AAA","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_16-04-35.png?v=1783591575","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ds200tbcag1aaa-rtd-termination-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}