{"product_id":"ge-ds200rtbag2aeb-relay-terminal-board","title":"GE DS200RTBAG2AEB Relay Terminal Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200RTBAG2AEB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200RTBAG2AEB\u003c\/strong\u003e Relay Terminal Board, operates as a dedicated hardware component for relay switching and external I\/O signal termination within GE Mark V and EX2000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200RTBAG2AEB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing Plants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard GE Mark V rack profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on active relay coil energization and backplane loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 percent, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eTerminal board with onboard electromechanical relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eGE Mark V and EX2000 turbine control architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Compatibility and Backplane Bus Signal Routing\u003c\/h3\u003e\n\u003cp\u003eIntegrated directly within GE Mark V and EX2000 control frameworks, the board provides firm terminal distribution routes that maintain deterministic signal velocities across multi-card backplane buses. Firmware flash compatibility and hardware revision alignment ensure that switching logic coordinates precisely with core processor execution cycles. Terminal block wiring paths are laid out to minimize parasitic capacitance, preserving signal integrity across high-speed digital I\/O lines and safeguarding against communication jitter during turbine protection sequence triggers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary system architectures compatible with the DS200RTBAG2AEB terminal board?\u003c\/p\u003e\n\u003cp\u003eA: This relay terminal board is engineered specifically for deployment within GE Mark V gas\/steam turbine control systems and EX2000 excitation control platforms.\u003c\/p\u003e\n\u003cp\u003eQ: How does the board handle extreme environmental conditions during operation?\u003c\/p\u003e\n\u003cp\u003eA: The hardware is rated for a wide operating temperature window ranging from -40 deg C to +85 deg C and tolerates up to 95 percent non-condensing relative humidity environments.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific wiring constraints to observe during terminal installation?\u003c\/p\u003e\n\u003cp\u003eA: Field wiring must be secured via standard screw terminals while maintaining proper separation between high-voltage relay switching circuits and low-voltage control logic lines to avoid crosstalk.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the DS200RTBAG2AEB securely inside designated control cabinet chassis or Mark V core enclosures using standard mounting standoffs. Ensure all incoming field signal lines are stripped to correct lengths and tightened to manufacturer torque specifications to prevent terminal loosening under continuous cabinet vibration. Verify ground continuity across the chassis backplane prior to applying system power.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48231409287358,"sku":"DS200RTBAG2AEB","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/Overview.png?v=1785399846","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ds200rtbag2aeb-relay-terminal-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}