{"product_id":"ge-ds200imcpg1cca-power-supply-interface-board","title":"GE DS200IMCPG1CCA Power Supply Interface Board","description":"\u003cp\u003eConfigured for power distribution and signal conditioning in Mark V Speedtronic turbine management systems, the \u003cstrong\u003eGE DS200IMCPG1CCA\u003c\/strong\u003e (\u003cstrong\u003eDS200IMCPG1CCA\u003c\/strong\u003e Power Supply Interface Board) provides direct physical\/electrical execution of power regulation and isolation within industrial turbine control architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eMark V Series assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMCP\u003c\/td\u003e\n\u003ctd\u003eIGBT Power Supply functional acronym\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eProduct grouping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003ePrimary functional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eSecondary functional revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eArtwork configuration revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200IMCPG1CCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DS200 board footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRack dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane bus communication velocity:\u003c\/strong\u003e The board maintains standardized signal timing for integration with the Mark V control bus, ensuring that power supply status and interface signals remain synchronized with the turbine management scan cycle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP deterministic networks:\u003c\/strong\u003e While utilizing legacy analog power regulation, the board architecture maintains the signal stability required for deterministic control loops, mitigating the risk of jitter in sensitive electronic interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O density scaling:\u003c\/strong\u003e The PCB layout integrates high-density power isolation and conditioning components, allowing for effective voltage management within the constrained cabinet space of the Mark V turbine control system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware flash compatibility:\u003c\/strong\u003e The board logic is engineered to maintain hardware-level compatibility with standard Mark V firmware, ensuring consistent operation across varied turbine excitation and power conversion requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this board require external power conditioning?\u003c\/p\u003e\n\u003cp\u003eA: The board provides internal isolation and conditioning for incoming power to protect sensitive downstream electronics. No external power conditioning is required beyond standard industrial power supply regulations.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board compatible with both AC and DC rack power configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the board is designed to support input power ranging from AC to DC depending on the specific rack configuration. Verify the rack output voltage matches the board’s design specifications before final installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Utilize the factory-drilled mounting holes to secure the board firmly into the designated Mark V rack slot. Ensure all mechanical fasteners are tightened to maintain a solid ground bond to the rack frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e A low-impedance ground connection between the PCB and the cabinet protective earth (PE) bus is mandatory. This bond is required to ensure electromagnetic interference (EMI) immunity and to maintain the reference stability for isolation circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain strict segregation between power-conditioned output paths and high-voltage input leads to prevent inductive noise injection into the control logic. Verify that all plug connections are fully seated before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48157269885118,"sku":"DS200IMCPG1CCA","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-13_15-22-25_0b731a78-c517-4376-ba0e-88b28a226475.png?v=1783936010","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ds200imcpg1cca-power-supply-interface-board","provider":"AutoOilTech Limited","version":"1.0","type":"link"}