{"product_id":"ge-ds200dtbcg1a-contact-output-termination-module","title":"GE DS200DTBCG1A Contact Output Termination Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200DTBCG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200DTBCG1\u003c\/strong\u003e Contact Output Termination Module, operates as a dedicated hardware component for relay signal and power distribution termination within Mark V turbine control systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \u0026amp; Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200\u003c\/td\u003e\n\u003ctd\u003eSeries Tag\u003c\/td\u003e\n\u003ctd\u003eMark V Series assembly and domestic original manufacture location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDTBC\u003c\/td\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eContact Output Termination Module assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG1\u003c\/td\u003e\n\u003ctd\u003eProduct Grouping\u003c\/td\u003e\n\u003ctd\u003eGroup one architecture variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eA-rated primary functional design revision level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200DTBCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Turbine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent panel enclosure format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3 inches in height x 11.5 inches in length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Capacity\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks with terminals for 110 signal wires each (up to 220 total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Elements\u003c\/td\u003e\n\u003ctd\u003e2 3-wire bayonet connectors, 1 2-wire bayonet connector, 10 jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Backplane Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe module integrates within Mark V industrial control architectures utilizing high-velocity backplane communication links, ensuring synchronized relay output switching across turbine management nodes. Profinet and EtherNet\/IP deterministic network integration frameworks support real-time status reporting of control outputs through dedicated interface connections such as the JS1-JS8 TCRA board relay signal connectors and the J8 TCPD solenoid power port. I\/O density scaling and firmware flash compatibility features maintain configuration integrity during operational cycles without compromising switching precision.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many signal wire connections are supported across the terminal blocks of the DS200DTBCG1A?\u003c\/p\u003e\n\u003cp\u003eA: The board features two terminal blocks, each accommodating up to 110 signal wires for a total capacity of 220 connections.\u003c\/p\u003e\n\u003cp\u003eQ: What is the specific purpose of the J15 and J16 connectors on the module assembly?\u003c\/p\u003e\n\u003cp\u003eA: J15 and J16 typically connect with each other to manage contact outputs #16, #17, and #18 within the Mark V drive assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Can this termination module be replaced while the Mark V rack is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. All power feeds to the rack must be locked out and verified using a meter to prevent electrical shock and circuit damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all system power feeds to the Mark V core and associated termination enclosures are locked out and tested for zero energy state.\u003c\/li\u003e\n\u003cli\u003eMount the board securely within the designated drive cabinet space, maintaining physical separation between signal wiring and high-voltage power cables to avoid electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate signal wires securely to blocks and map bayonet connectors (JS1-JS8, J8, J15, J16) according to legacy documentation layout.\u003c\/li\u003e\n\u003cli\u003eVerify all jumper settings and test relay output continuity using diagnostic software prior to system re-energization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":48180145422526,"sku":"DS200DTBCG1A","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/DS200DTBCG1AAA_32012202-f591-4581-8a50-7cda408d1372.png?v=1784625678","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-ds200dtbcg1a-contact-output-termination-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}