{"product_id":"ge-369-hi-r-m-0-p-0-e-multilin-motor-protection","title":"GE 369-HI-R-M-0-P-0-E Multilin Motor Protection","description":"\u003cp\u003eThe \u003cstrong\u003eGE Multilin 369-HI-R-M-0-P-0-E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e369-HI-R-M-0-P-0-E\u003c\/strong\u003e Motor Protection Relay, serves as the primary \u003cstrong\u003e369\u003c\/strong\u003e Motor Protection Relay utilized to execute comprehensive motor monitoring, thermal tracking, and integrated network communication across industrial control and power distribution platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 369 series utilizes explicit alphanumeric codes within its ordering matrix to define the integrated hardware options and functionality block baseline:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e369\u003c\/strong\u003e: Core basic unit designator for the Motor Protection\/Management Relay series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHI\u003c\/strong\u003e: Universal high-voltage control power supply block (50-300 VDC \/ 60-265 VAC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Optional 12 RTD inputs hardware module built directly into the chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e: Optional full electrical metering package module enabled.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard serial ports only; no optional Fiber Optic Port hardware installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e: Optional specialized network protocol interface board equipped.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0\u003c\/strong\u003e: Standard assembly; no harsh environment conformal coating option applied.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Enhanced diagnostics functionality equipped with an enhanced faceplate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-M-0-P-0-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.50 lbs (3.40 kg) net weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Multilin 369 series panel-mount drawout case footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial switchgear environmental parameters apply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eControl Power range: 50-300 VDC \/ 60-265 VAC at 50\/60 Hz frequency bounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMotor Protection Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 built-in, independent Resistance Temperature Detector channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Option\u003c\/td\u003e\n\u003ctd\u003eIntegrated operational voltage, current, and power monitoring package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Communication Ports\u003c\/td\u003e\n\u003ctd\u003eRear copper communication channels with integrated protocol expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Assembly\u003c\/td\u003e\n\u003ctd\u003eEnhanced diagnostics system with an enhanced faceplate layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Power System Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity and Density Scaling\u003c\/strong\u003e The relay aggregates analog sensory parameters through its 12 built-in RTD channels and integrated metering package concurrently. It converts physical stator temperatures, line voltages, and phase currents into digital registers, executing local protection state calculations without introducing latency into the downstream programmable logic controller (PLC) or supervisory network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Firmware Flash Compatibility\u003c\/strong\u003e The system integrates a dedicated protocol expansion board alongside standard serial options, supporting cyclic data exchange loops with master control nodes. The internal firmware maps power factor, power consumption (kW\/kVA), and thermal capacity variables directly onto network telegrams, ensuring deterministic output relay contact execution under severe overload conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific data variables are added to the system registers by the \"M\" metering package suffix?\u003c\/p\u003e\n\u003cp\u003eA: The \"M\" option installs the hardware instrumentation components required to calculate three-phase electrical power parameters. It monitors real-time bus voltage, active\/reactive\/apparent power metrics (kW\/kVar\/kVA), frequency variations, and power factor variables alongside the standard phase current protection functions.\u003c\/p\u003e\n\u003cp\u003eQ: How does the \"P\" option suffix alter the default communication capabilities of the relay?\u003c\/p\u003e\n\u003cp\u003eA: The \"P\" designator indicates the factory installation of an advanced network interface card. This enables the relay to transcend basic point-to-point Modbus RTU communications, allowing it to interface directly with specialized industrial bus topologies for high-density diagnostic reporting to plant DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment, Drawout Seating, and Enclosure Mounting\u003c\/strong\u003e Cut out the panel door to match the vertical layout of the 369 drawout case. Guide the main relay case straight through the opening until the flange seats flush against the panel face, then tighten the rear mounting bracket clamps to lock the assembly against heavy structural switchgear vibrations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Routing, Noise Suppression, and Shield Grounding Blocks\u003c\/strong\u003e Route the low-voltage RTD inputs and network data links through dedicated grounded wireways separate from heavy three-phase motor leads. Terminate all shielded twisted-pair drain wires directly at the central protective earth ground bus terminal to suppress induced radio frequency or electromagnetic interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":47621477269694,"sku":"369-HI-R-M-0-P-0-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-06-11_17-19-50_adc17154-dfca-427a-9020-6d2b84c97574.png?v=1781171919","url":"https:\/\/www.autooiltech.com\/ar\/products\/ge-369-hi-r-m-0-p-0-e-multilin-motor-protection","provider":"AutoOilTech Limited","version":"1.0","type":"link"}