{"product_id":"emerson-ve5132-deltav-bulk-power-supply-redundancy-module","title":"Emerson VE5132 DeltaV Bulk Power Supply Redundancy Module","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson VE5132\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE5132\u003c\/strong\u003e Power Supply Redundancy Module, operates as a dedicated hardware component for decoupling and monitoring parallel bulk power sources within DeltaV distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVE5132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson (DeltaV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower Supply Redundancy Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 28 VDC (Dual inputs, 20 A maximum per input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 to 28 VDC (Input voltage minus diode drop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A maximum total output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal coating against atmospheric contaminants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry contact relay output (Vout OK) and LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Power Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe VE5132 module manages redundant bulk power configurations to prevent single-source failures from disrupting system power.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Input Decoupling:\u003c\/strong\u003e Employs high-current decoupling diodes to isolate two independent 12-28 VDC power supplies, preventing a short circuit on one input line from pulling down the active output bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Diagnostic Isolation:\u003c\/strong\u003e The internal diagnostic monitor circuit is isolated from the main power path, routing system fault signals safely to DCS controller input channels via a dry contact relay rated for low-voltage signaling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Protection:\u003c\/strong\u003e Standard industrial conformal coating safeguards internal copper traces and surface-mount components from moisture-induced leakage currents and chemical degradation in harsh Class G3 environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the VE5132 module regulate or boost the output voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The VE5132 is a passive diode-or redundancy module. The output voltage directly tracks the input voltage, minus a nominal silicon diode forward voltage drop (typically 0.5 to 0.8 VDC depending on the load current).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current limit supported on each individual input terminal?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Each input path (Input 1 and Input 2) is designed to handle up to 20 A continuously. To achieve the full 40 A rating at the output terminal, both inputs must be powered by separate, load-sharing bulk supplies.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Conductor Termination:\u003c\/strong\u003e Secure all high-current input and output wires to the heavy-duty screw terminals, ensuring a tightening torque of 0.8 N-m (7 in-lb) to prevent loose, high-resistance connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Earthing Verification:\u003c\/strong\u003e Ground the module's metal housing directly through its integrated DIN-rail clamping clip, verifying that the rail is bonded to the primary cabinet ground bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management spacing:\u003c\/strong\u003e Maintain a minimum clear distance of 40 mm (1.5 in) on the left and right sides, and 80 mm (3.1 in) above and below the module to allow sufficient airflow for passive convective heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48170712498366,"sku":"VE5132","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/VE5132_2.png?v=1784280622","url":"https:\/\/www.autooiltech.com\/ar\/products\/emerson-ve5132-deltav-bulk-power-supply-redundancy-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}