{"product_id":"emerson-ve3005-deltav-controller-md","title":"Emerson VE3005 DeltaV Controller MD","description":"\u003cp\u003eConfigured for local control execution in DeltaV network platforms, the \u003cstrong\u003eEmerson VE3005\u003c\/strong\u003e (\u003cstrong\u003eVE3005\u003c\/strong\u003e Controller MD) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVE3005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternate Part Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKJ2003X1-BA2, 12P2093X112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ DeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eController MD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplied via 2-wide Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard M-Series controller footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Network Execution \u0026amp; Protocol Management\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Channel-to-Channel Isolation:\u003c\/strong\u003e The controller backplane interface incorporates optical and galvanic isolation, protecting the internal logic and microprocessor from high-voltage transients on the power or carrier bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Coexistence:\u003c\/strong\u003e Onboard power distribution and processing circuits feature high-frequency filtering to suppress electromagnetic noise, preventing interference with analog 4-20 mA HART loop protocol lines on neighboring I\/O cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeterministic Control Execution:\u003c\/strong\u003e Processes configuration databases, executing continuous and discrete control logic cycles in real time to synchronize state data with the active I\/O subsystem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the VE3005 controller be hot-swapped while under power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, the VE3005 supports hot-swapping. When mounted on a redundant controller carrier, the standby module will instantly assume active control if the primary controller is extracted, maintaining continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the significance of the secondary part numbers KJ2003X1-BA2 and 12P2093X112?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e These represent the internal manufacturing and assembly hardware identification numbers used by Emerson for the physical circuit board and casing of this specific controller model.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Slot Insertion:\u003c\/strong\u003e Insert the controller into the designated left or right slot of the 2-wide Power\/Controller Carrier. Push firmly until the backplane connectors align and seat completely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Screw Retention:\u003c\/strong\u003e Secure the module to the carrier by tightening the integrated captive screws at the top and bottom of the module casing to resist industrial vibration profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding Verification:\u003c\/strong\u003e Ensure the DIN rail hosting the carrier is properly bonded to the cabinet's main instrument ground bus to guarantee structural shield dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Temperature Control:\u003c\/strong\u003e Maintain adequate ventilation clearance around the controller carrier to prevent heat buildup, keeping the operating ambient temperature within the specified -40 to +70 deg C envelope.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48164852596926,"sku":"VE3005","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_17-00-44_3d1b7b82-948d-4a32-bdee-81acdede9c71.png?v=1784108230","url":"https:\/\/www.autooiltech.com\/ar\/products\/emerson-ve3005-deltav-controller-md","provider":"AutoOilTech Limited","version":"1.0","type":"link"}