{"product_id":"emerson-ez1900-080-extension-cable","title":"Emerson EZ1900-080 Extension Cable","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson EZ1900-080\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eEZ1900-080\u003c\/strong\u003e extension cable, operates as a dedicated hardware component for vibration signal transmission within AMS EZ 1000 monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEZ1900-080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg (approximate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 meters length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +150 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003eFEP (Fluorinated Ethylene Propylene)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor\u003c\/td\u003e\n\u003ctd\u003eNon-armored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 (when installed correctly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Path Impedance and Transmission Integrity\u003c\/h3\u003e\n\u003cp\u003eThe extension harness maintains low signal attenuation across the full 8 meters span to preserve dynamic vibration waveforms generated by proximity probes. Utilizing FEP insulation material, the assembly exhibits chemical resistance against synthetic lubricants, hydraulic fluids, and hydrocarbon exposures typical of turbine and compressor skids. Connector interfaces are engineered to match characteristic impedance requirements of the AMS EZ 1000 platform, preventing standing waves and reflection anomalies at high frequency response thresholds. Shielding continuity is maintained continuously through the mated connector shells to suppress electromagnetic interference (EMI) originating from nearby variable frequency drives and high-voltage power conduits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the cable length be modified or spliced on site?\u003c\/p\u003e\n\u003cp\u003eA: No. Splicing or cutting the FEP cable alters the total electrical capacitance and characteristic impedance, which introduces phase distortion and amplitude errors in vibration measurements. Replacement must be performed with a factory-matched length unit.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum permissible bending radius during physical routing?\u003c\/p\u003e\n\u003cp\u003eA: The minimum dynamic bend radius is 50 mm, and the minimum static bend radius is 30 mm. Exceeding these limits can compromise the inner conductor geometry and outer FEP jacket integrity.\u003c\/p\u003e\n\u003cp\u003eQ: Does the assembly require external grounding separate from the sensor housing?\u003c\/p\u003e\n\u003cp\u003eA: Grounding is established through the designated shield connection tied to the converter chassis ground pin at the panel end, ensuring single-point grounding loops are avoided.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRoute the cable away from high-voltage power lines, variable frequency drive output cables, and heavy inductive load wiring to prevent electromagnetic induction coupling into the signal path.\u003c\/li\u003e\n\u003cli\u003eSecure the cable harness at intervals not exceeding 0.5 meters using non-abrasive industrial cable ties or stainless steel clamps designed for high-temperature environments.\u003c\/li\u003e\n\u003cli\u003eInspect mating connector pins for moisture, particulate contamination, or oxidation prior to physical engagement. Thread coupling rings manually until fully seated to maintain the IP66 ingress protection seal.\u003c\/li\u003e\n\u003cli\u003eVerify loop DC resistance and shield isolation using a high-impedance digital multimeter prior to system power-up and calibration execution.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":48179988922558,"sku":"EZ1900-080","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/EZ1080-RM-00-010_f78d6f72-b493-47db-a80e-2a500505a6b2.png?v=1784627839","url":"https:\/\/www.autooiltech.com\/ar\/products\/emerson-ez1900-080-extension-cable","provider":"AutoOilTech Limited","version":"1.0","type":"link"}