{"product_id":"bently-nevada-330905-00-05-10-02-00-3300-nsv-proximity-probes","title":"Bently Nevada 330905-00-05-10-02-00 3300 NSv Proximity Probes","description":"\u003ch2\u003eBently Nevada 330905-00-05-10-02-00 3300 NSv Proximity Probes\u003c\/h2\u003e\n\u003cp\u003eConfigured for displacement measurement in NSv eddy‑current monitoring loops, the \u003cstrong\u003eBently Nevada 330905-00-05-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330905\u003c\/strong\u003e proximity probe) provides direct physical sensing through a controlled impedance path and stable gap‑voltage behavior required by 3300 NSv signal conditioning modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330905\u003c\/strong\u003e = 3300 NSv proximity probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e = Unthreaded length 0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e = Case length 50 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e = Total cable length 1.0 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e = Miniature coaxial ClickLoc connector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e = Standard version, no agency approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e330905-00-05-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified (follow standard NSv probe handling limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eCase length 50 mm, cable length 1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-34 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive probe, energized through proximitor excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThread Size\u003c\/th\u003e\n\u003ctd\u003eM10 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Type\u003c\/th\u003e\n\u003ctd\u003eStandard coaxial, ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003e3300 NSv proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy‑Current Scaling and Gap‑Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe maintains calibrated eddy‑current scaling when paired with matched NSv extension cables and proximitor modules. Gap‑voltage behavior aligns with the −10 VDC reference used in NSv systems, supporting consistent displacement interpretation across rotor‑dynamic monitoring applications. The M10 x 1 threaded body ensures stable mechanical seating, while controlled coaxial impedance minimizes cross‑talk within multi‑channel racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the probe require a specific proximitor model for correct scaling? A: Yes. NSv probes must be paired with NSv‑rated extension cables and proximitor modules to maintain factory‑matched impedance and linearity.\u003c\/p\u003e\n\u003cp\u003eQ: Can the ClickLoc connector be re‑terminated in the field? A: No. The connector is factory‑assembled. Field re‑termination may alter impedance and degrade displacement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Will cable routing near high‑current conductors affect the signal? A: Yes. Eddy‑current systems are sensitive to electromagnetic interference; maintain separation from high‑current wiring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure full seating of the M10 x 1 threaded section to maintain probe‑to‑shaft alignment. Route the coaxial cable with gentle bend radii to preserve impedance. Bond shielding at the proximitor end only to avoid ground‑loop formation. Maintain at least several centimeters of separation from high‑current conductors or variable‑frequency drive outputs. Apply strain relief to prevent vibration‑induced connector motion.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48191192105150,"sku":"330905-00-05-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/bently-nevada-330905-00-25-05-02-00-3300-nsv-proximity-probes-dlpeak2fo3d.png?v=1758880772","url":"https:\/\/www.autooiltech.com\/ar\/products\/bently-nevada-330905-00-05-10-02-00-3300-nsv-proximity-probes","provider":"AutoOilTech Limited","version":"1.0","type":"link"}