{"product_id":"bently-nevada-330104-00-24-10-02-00-proximity-probes","title":"Bently Nevada | 330104-00-24-10-02-00 | Proximity Probes","description":"\u003ch2\u003eBently Nevada 330104-00-24-10-02-00 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-00-24-10-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e proximity probe, serves as the primary 8 mm eddy‑current sensing element used to execute shaft‑vibration and rotor‑position measurements across 3300 XL monitoring platforms. This configuration implements a 0 mm unthreaded length, 240 mm case length, 1.0 m system length, and a miniature coaxial ClickLoc connector with FluidLoc cable protection.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330104\u003c\/strong\u003e — 3300 XL 8 mm proximity probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e — Unthreaded length = 0 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24\u003c\/strong\u003e — Case length = 240 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e — Total system length = 1.0 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e — Miniature coaxial ClickLoc connector, standard cable, FluidLoc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e — No agency approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e330104-00-24-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e240 mm case length; 8 mm tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePassive probe; powered by proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eProbe Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e3300 XL 8 mm eddy‑current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable\/System Length\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCable Type\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eFluidLoc standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003ePPS probe tip; stainless steel case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy‑Current Scaling and Rotor‑Dynamic Measurement Behavior\u003c\/h3\u003e\n\u003cp\u003e3300 XL probes follow a standardized eddy‑current scaling curve that ensures consistent displacement interpretation across the 8 mm measurement range. The proximitor drives the probe toward a nominal \u003cstrong\u003e−10 VDC gap‑voltage target\u003c\/strong\u003e, establishing linear response for rotor‑dynamic tracking. The extended 240 mm case length supports installations requiring deeper mechanical reach into bearing housings or brackets. The ClickLoc connector maintains coaxial shielding continuity, while the FluidLoc cable design reduces contamination ingress and preserves impedance stability. These characteristics suppress cross‑talk and micro‑motion noise in multi‑probe configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the probe be replaced while the proximitor is energized?\u003c\/strong\u003e A: No. Replacement should only occur with the channel de‑energized to avoid transient gap‑voltage excursions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does modifying cable length affect calibration?\u003c\/strong\u003e A: Yes. System length is factory‑matched. Any non‑standard extension alters impedance and shifts the scaling curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is firmware required for probe compatibility?\u003c\/strong\u003e A: No. The probe contains no firmware. Compatibility is determined solely by proximitor and monitor configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the threaded M10 × 1 case is seated cleanly in a burr‑free mounting bore. Maintain proper standoff distance before verifying gap voltage. Route coaxial cable away from high‑current conductors to minimize induced noise. Bond shielding at the proximitor end only to prevent ground loops. Avoid sharp cable bends that may alter impedance. Confirm ClickLoc connector engagement before commissioning.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48184084332734,"sku":"330104-00-24-10-02-00","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/bently-nevada-330104-02-24-10-01-00-3300-xl-8-mm-proximity-probes-dothnxzgoqp.png?v=1759044078","url":"https:\/\/www.autooiltech.com\/ar\/products\/bently-nevada-330104-00-24-10-02-00-proximity-probes","provider":"AutoOilTech Limited","version":"1.0","type":"link"}