{"product_id":"anb10d-415-yokogawa-node-unit","title":"ANB10D-415 Yokogawa Node Unit","description":"\u003cp\u003eConfigured for high-speed field bus communication in CENTUM VP platforms, the \u003cstrong\u003eYokogawa ANB10D-415\/CU2N\/NDEL\u003c\/strong\u003e (\u003cstrong\u003eANB10D-415\u003c\/strong\u003e Node Unit) provides direct physical\/electrical execution of data exchange between the ESB bus and field I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit for ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eSoftware License for Node Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-415\/CU2N\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard node unit profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem dependent (100 - 120 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The unit facilitates transparent HART data transmission from connected I\/O channels to the host DCS, maintaining signal integrity for device-level diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The node interface supports deterministic fieldbus traffic, ensuring consistent update rates for process variables across the ESB bus architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The internal backplane design provides galvanic isolation to mitigate common-mode noise and prevent ground potential differences from affecting the high-speed bus communication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The unit interfaces with I\/O modules to support thermocouple CJC, ensuring temperature measurement accuracy by referencing local ambient thermal sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the dual-redundant power supplies be removed during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The power supply units support hot-swapping to ensure continuous node availability during maintenance without interruption of the ESB bus communication.\u003c\/p\u003e\n\u003cp\u003eQ: Is the NDEL license code required for all node expansion scenarios?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The \/NDEL option indicates a mandatory software license that must be installed in the CENTUM VP system database to enable communication with the expanded node count.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the ANB10D unit into a standard 19-inch equipment rack. Use all required M5 mounting screws to ensure structural stability and mitigate the effects of mechanical vibration on bus connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis ground terminal to the main system protective earth (PE) bus. A solid, low-impedance ground connection is required to meet EMI\/EMC standards for the high-speed ESB bus interface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Maintain strict separation between ESB bus cabling and high-power AC\/DC lines to prevent electromagnetic interference. Ensure all ESB bus connectors are fully seated and free of debris to maintain signal integrity across the bus segment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48160590627006,"sku":"ANB10D-415\/CU2N\/NDEL","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/screenshot_2026-07-09_16-36-30_70c012bc-3eb4-449d-900e-689a6b10f824.png?v=1784007607","url":"https:\/\/www.autooiltech.com\/ar\/products\/anb10d-415-yokogawa-node-unit","provider":"AutoOilTech Limited","version":"1.0","type":"link"}