{"product_id":"allen-bradley-1715-aentr-ethernet-communication-modules","title":"Allen-Bradley 1715-AENTR Ethernet Communication Modules","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 1715-AENTR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1715-AENTR\u003c\/strong\u003e Communication Adapter, operates as a dedicated hardware component for network interface execution within Allen-Bradley 1715 Redundant I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1715-AENTR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 1715 Adapter Module Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e11.4 W max at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology Support\u003c\/td\u003e\n\u003ctd\u003eDevice Level Ring (DLR), Star\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Support\u003c\/td\u003e\n\u003ctd\u003eControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e380 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Style\u003c\/td\u003e\n\u003ctd\u003eOpen-Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks \u0026amp; Backplane Velocity\u003c\/h3\u003e\n\u003cp\u003eThe 1715-AENTR network interface module connects 1715 redundant I\/O backplanes directly to EtherNet\/IP deterministic networks, coordinating continuous packet transfers over dual-channel media. Supporting Device Level Ring (DLR) and star network topologies, the adapter maintains fault-tolerant network execution and backplane bus communication velocity across linked ControlLogix platforms. Built-in diagnostic capabilities and plug-and-play parameter synchronization support high I\/O density scaling without degrading network scan cycle times.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What network topologies are supported by the dual-channel 1715-AENTR adapter?\u003c\/p\u003e\n\u003cp\u003eA: The module features 2 EtherNet\/IP ports supporting both fault-tolerant Device Level Ring (DLR) and standard star network topologies.\u003c\/p\u003e\n\u003cp\u003eQ: What is the current draw and operating voltage requirement for the 1715-AENTR?\u003c\/p\u003e\n\u003cp\u003eA: The adapter operates on an external supply voltage of 18 to 30 VDC with a nominal current draw of 380 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the 1715-AENTR adapter on a standard DIN rail inside an enclosure, ensuring proper clip engagement for structural stability.\u003c\/li\u003e\n\u003cli\u003eConnect the main 24 VDC power feed to the supply terminals, keeping input voltage strictly within the 18 to 30 VDC range.\u003c\/li\u003e\n\u003cli\u003eAttach EtherNet\/IP cables to both channels when configuring Device Level Ring (DLR) topology to preserve network redundancy paths.\u003c\/li\u003e\n\u003cli\u003eEnsure continuous low-impedance grounding of the DIN rail to suppress electro-magnetic interference across high-speed network channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":48793755615422,"sku":"1715-AENTR","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/1715-AENTR_ed37f4b0-7137-4efe-ac71-3e31984a11f3.png?v=1787881113","url":"https:\/\/www.autooiltech.com\/ar\/products\/allen-bradley-1715-aentr-ethernet-communication-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}