{"product_id":"abb-icso16n1-binary-input-module","title":"ABB ICSO16N1 Binary Input Module","description":"\u003cp\u003eConfigured for 220 VAC discrete signal sensing in PLC control architectures, the \u003cstrong\u003eABB ICSO16N1\u003c\/strong\u003e (\u003cstrong\u003eFPR3313101R0056\u003c\/strong\u003e Binary Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Attribute\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eICSO16N1\u003c\/td\u003e\n\u003ctd\u003eBase 16-channel discrete input card architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFPR3313101R0056\u003c\/td\u003e\n\u003ctd\u003eEngineering part identification number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e220VAC\u003c\/td\u003e\n\u003ctd\u003eField signal input voltage threshold specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBIN.A-MODUL\u003c\/td\u003e\n\u003ctd\u003eBinary digital input processing module type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eICSO16N1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Rack-Mount Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e220 VAC nominal input, 5 W internal logic power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 discrete input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e220 VAC Binary\/Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Identification\u003c\/td\u003e\n\u003ctd\u003eFPR3313101R0056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Backplane Communication \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module scans 16 discrete 220 VAC field inputs simultaneously, executing optical isolation to protect internal backplane logic from line voltage surges. High-speed signal conditioning circuits convert high-voltage AC inputs into low-voltage logic states without thermal degradation. Backplane bus communication velocity allows rapid transfer of binary input status bits to the primary CPU module, while firmware flash compatibility maintains synchronous scan cycles across multi-rack I\/O density scaling configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary input voltage rating for the 16 binary channels?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 16 input channels is designed to sense standard 220 VAC discrete signals from field switches and relay contacts.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for the ICSO16N1 module during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Module replacement requires de-energizing both backplane rack power and external 220 VAC field input loops to prevent arcing and pin damage.\u003c\/p\u003e\n\u003cp\u003eQ: How are field transients isolated from the sensitive backplane logic?\u003c\/p\u003e\n\u003cp\u003eA: Internal optocouplers deliver channel-to-backplane galvanic isolation, blocking field-side voltage spikes from reaching the main rack bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all 220 VAC power sources and system rack auxiliary supplies before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the designated rack slot guides and push firmly until the rear backplane connectors are fully engaged.\u003c\/li\u003e\n\u003cli\u003eTighten top and bottom module retaining screws to 0.6 Nm to ensure mechanical stability and chassis ground continuity.\u003c\/li\u003e\n\u003cli\u003eRoute 220 VAC field input signal conductors through independent wiring channels separate from low-voltage DC logic and communication lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48786272092350,"sku":"ICSO16N1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/ICSO16N1_4d311c89-4601-400a-a565-419b15963653.png?v=1787710172","url":"https:\/\/www.autooiltech.com\/ar\/products\/abb-icso16n1-binary-input-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}