{"product_id":"900u02-0100-honeywell-controledge-hc900-io-modules","title":"900U02-0100 | Honeywell | ControlEdge HC900 IO Modules","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Honeywell\u003cstrong\u003e 900U02‑0100 \u003c\/strong\u003eSIL UIO Module provides 16 channels of line‑monitored 4–20 mA analog current inputs for ControlEdge HC900 systems, delivering high‑resolution measurement and safety‑rated signal acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e: 900U02‑0100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: ControlEdge HC900 I\/O Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eItem\u003c\/strong\u003e: SIL UIO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: Current (2‑wire, 3‑wire, or 4‑wire devices)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e: 16 maximum per module (line monitored)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e: 16‑bit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e: 4–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Monitoring\u003c\/strong\u003e: Line‑monitoring capability for safety applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e: ControlEdge HC900 controller racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e: 2 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSIL‑Rated Input\u003c\/strong\u003e: Supports safety‑integrity applications with monitored current loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh‑Resolution Measurement\u003c\/strong\u003e: 16‑bit A\/D conversion for precise analog acquisition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible Wiring\u003c\/strong\u003e: Accepts 2‑wire, 3‑wire, and 4‑wire field devices\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLine Monitoring\u003c\/strong\u003e: Detects open‑circuit and fault conditions in current loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHC900 Integration\u003c\/strong\u003e: Fully compatible with ControlEdge HC900 I\/O subsystem\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability\u003c\/strong\u003e: Designed for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ – Common Questions\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_the_900U02-0100_for\u003c\/strong\u003e: It acquires 4–20 mA analog signals with SIL‑rated line monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDoes_it_support_multiple_wiring_types\u003c\/strong\u003e: Yes, it supports 2‑wire, 3‑wire, and 4‑wire devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat_is_the_resolution\u003c\/strong\u003e: It uses a 16‑bit A\/D converter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHow_many_channels_are_available\u003c\/strong\u003e: Up to 16 monitored analog input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIs_it_for_HC900\u003c\/strong\u003e: Yes, it is part of the ControlEdge HC900 I\/O family.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48022051029182,"sku":"900U02-0100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/900A16-0101_1.jpg?v=1782287705","url":"https:\/\/www.autooiltech.com\/ar\/products\/900u02-0100-honeywell-controledge-hc900-io-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}