{"product_id":"5462-948-woodward-8-channel-thermocouple-card","title":"Woodward 5462-948 8-Channel Thermocouple Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward 5462-948 is an 8-channel thermocouple (T\/C) input card designed for precision temperature monitoring within industrial governor control systems. This module provides high-resolution signal processing for thermocouple inputs, ensuring reliable data acquisition for critical turbine and engine management applications. Engineered for robust performance, the unit supports a wide input range and maintains high accuracy under varying environmental conditions.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent input channels for thermocouple sensing.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 16-bit analog-to-digital conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated channel-to-bus isolation rated at 500 V dc.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance of 10 MΩ to minimize signal loading.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard 24 V dc rack power supply environments.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range suitable for industrial control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e5462-948\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 to +80 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% FSR ±1 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon-mode Voltage\u003c\/td\u003e\n\u003ctd\u003e±300 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V dc (Channel-to-Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Consumption\u003c\/td\u003e\n\u003ctd\u003e0.25 A @ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system rack is powered down before inserting or removing the 5462-948 module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power supply is stable at 24 V dc before applying power to the module.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for thermocouple wiring to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow within the cabinet to keep the module within its specified operating temperature range of 0 to +60 degC.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe procedures to protect sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the Woodward 5462-948?\u003c\/strong\u003e\u003cbr\u003eThe 5462-948 is an 8-channel thermocouple input card used to interface temperature sensors with Woodward governor control systems for precise engine or turbine monitoring.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external isolation?\u003c\/strong\u003e\u003cbr\u003eNo, the module features built-in channel-to-bus isolation rated at 500 V dc, simplifying integration into existing control loops.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the typical power consumption for this card?\u003c\/strong\u003e\u003cbr\u003eThe module consumes 0.25 A at 24 V dc when operating within its specified parameters.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48821261402302,"sku":"5462-948","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_7f08a92b-8e1e-46f9-aa12-23895b7df7bc.jpg?v=1788228184","url":"https:\/\/www.autooiltech.com\/ar\/products\/5462-948-woodward-8-channel-thermocouple-card","provider":"AutoOilTech Limited","version":"1.0","type":"link"}