{"product_id":"3bse008510r1-abb-do810-16-channel-digital-output-module","title":"ABB 3BSE008510R1 DO810 Digital Output Module","description":"\u003cp\u003eThe ABB DO810 (3BSE008510R1) is a high-performance 16-channel digital output module designed for the S800 I\/O system. This module facilitates the transmission of digital control signals to field-level components, including relays, contactors, and visual indicators. Engineered for robust industrial environments, it features two isolated groups of eight channels, each equipped with process voltage supervision to ensure system integrity.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel digital output configuration for 24 V DC current sourcing.\u003c\/li\u003e\n\u003cli\u003eTwo independently isolated groups of 8 channels.\u003c\/li\u003e\n\u003cli\u003eIntegrated process voltage supervision for each channel group.\u003c\/li\u003e\n\u003cli\u003eOutput Status LED indicators for local diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eOutput Set to Predetermined state (OSP) functionality for safe failure mode management.\u003c\/li\u003e\n\u003cli\u003eComprehensive protection against short-circuits, over-voltage, and over-temperature conditions.\u003c\/li\u003e\n\u003cli\u003eHigh-side driver architecture with inductive load suppression and EMC protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBurner Management Systems (BMS) for sequencing fuel valves and ignition hardware.\u003c\/li\u003e\n\u003cli\u003ePump and compressor sequencing for large-scale motor control.\u003c\/li\u003e\n\u003cli\u003eTurbine auxiliary control, including hydraulic pumps and motorized valve actuators.\u003c\/li\u003e\n\u003cli\u003eSubstation automation for triggering circuit breakers and electrical isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO810 \/ 3BSE008510R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (10 to 30 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing the module from the I\/O rack.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for mounting on the S800 I\/O mounting base; ensure proper seating to maintain electrical connection to the ModuleBus.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field wiring to minimize EMI in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for ventilation to ensure operation within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eVerify that the external process voltage supply is within the 10-30 V DC range to prevent false supervision error signals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the DO810 module?\u003c\/h3\u003e\u003cp\u003eThe DO810 acts as a digital interface between the control system and field devices, providing 16 channels of 24 V DC sourcing output to drive various industrial loads.\u003c\/p\u003e\u003ch3\u003eHow are the outputs protected?\u003c\/h3\u003e\u003cp\u003eEach channel utilizes a high-side driver that includes built-in protection against short-circuits, over-temperature, and over-voltage, alongside inductive load suppression.\u003c\/p\u003e\u003ch3\u003eWhat is the purpose of the OSP function?\u003c\/h3\u003e\u003cp\u003eThe Output Set to Predetermined (OSP) state ensures that if a communication failure or watchdog timer expiration occurs, the module automatically transitions outputs to a pre-configured safe state.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48851889946814,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/wm_1_f558ef23-b653-477f-b727-5362249bf058.jpg?v=1788769936","url":"https:\/\/www.autooiltech.com\/ar\/products\/3bse008510r1-abb-do810-16-channel-digital-output-module","provider":"AutoOilTech Limited","version":"1.0","type":"link"}