{"product_id":"2mlf-ad16a-honeywell-masterlogic-200-analog-input-modules","title":"2MLF-AD16A | Honeywell | MasterLogic-200 Analog Input Modules","description":"\u003ch2\u003eHoneywell 2MLF‑AD16A MasterLogic‑200 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 2MLF‑AD16A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2MLF‑AD16A\u003c\/strong\u003e analog input module, serves as a 16‑channel voltage\/current acquisition unit used to execute multi‑format analog signal conversion across MasterLogic‑200 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e2MLF‑AD16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eMasterLogic‑200 Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e0.115 kg (shipping weight 2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e−25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH, non‑condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH, non‑condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003eNo corrosive gas or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eBelow 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination Level\u003c\/th\u003e\n\u003ctd\u003eBelow 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eDC 5 V, 330 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eMasterLogic‑200 Analog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannels\u003c\/th\u003e\n\u003ctd\u003e16 channels per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e±0.2% @ 25 ±5 deg C; ±0.3% @ 0–55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Conversion Speed\u003c\/th\u003e\n\u003ctd\u003e500 µs per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation Method\u003c\/th\u003e\n\u003ctd\u003ePhoto‑coupler isolation between input terminal and PLC power (no channel‑to‑channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Block\u003c\/th\u003e\n\u003ctd\u003e32‑point terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Addressing\u003c\/th\u003e\n\u003ctd\u003eFixed 64 points; variable 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ Deterministic Network Behavior\u003c\/h3\u003e\n\u003cp\u003eAs part of the MasterLogic‑200 architecture, the module aligns with Honeywell’s deterministic industrial‑network conventions. When deployed in systems using \u003cstrong\u003eProfinet\u003c\/strong\u003e or similar deterministic Ethernet structures, the CPU maintains stable scan‑cycle timing and predictable analog refresh behavior. The module’s photo‑coupler isolation supports \u003cstrong\u003eI\/O density scaling\u003c\/strong\u003e across large multi‑rack configurations without introducing channel‑to‑channel interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 2MLF‑AD16A be hot‑swapped during operation?\u003c\/strong\u003e A: No. The module must be inserted or removed only when the MasterLogic‑200 rack is de‑energized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 500 µs\/channel conversion speed affect controller scan timing?\u003c\/strong\u003e A: Conversion speed determines how quickly each analog channel updates. Overall scan timing depends on the controller’s configured I\/O strategy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle channel isolation?\u003c\/strong\u003e A: Photo‑coupler isolation is provided between input terminals and PLC power. Channels themselves are not isolated from each other.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute analog wiring separately from high‑voltage conductors to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eUse shielded cable and bond the shield at a single termination point to prevent circulating currents.\u003c\/li\u003e\n\u003cli\u003eEnsure proper seating of the 32‑point terminal block before energizing the rack.\u003c\/li\u003e\n\u003cli\u003eMaintain environmental conditions within specified temperature, humidity, and contamination limits.\u003c\/li\u003e\n\u003cli\u003eVerify that input signals remain within the module’s supported analog ranges and absolute maximum limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48207283683518,"sku":"2MLF-AD16A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/1145\/5422\/files\/2MLL-C42B_7adb69ed-d90f-4eb7-9f5e-8465350ff588.png?v=1784280824","url":"https:\/\/www.autooiltech.com\/ar\/products\/2mlf-ad16a-honeywell-masterlogic-200-analog-input-modules","provider":"AutoOilTech Limited","version":"1.0","type":"link"}